Overview

Basic Info.

Model NO.
AFDD2-40 1P+N B/C6/0.03A
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
Afdd
Poles Number
2
Type
Circuit Breaker
Function
Arc Fault Circuit Interrupter
Certification
CB
Frequency
50Hz
Rated Voltage
230V
Transport Package
Standard
Specification
32A
Trademark
GEYA
Origin
Zhe

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
1.000kg

Product Description

Arc Fault Breaker Geya 32A Zhe 25A Afdd Protection Gddf
This link price is only for AFDD2-40  1P+N B/C6/0.03A. If you need other specifications, please feel free to contact us!
Product Description

Overview:
AFDD-32 incorporating MCB and arc fault detection module, provides protection against short circuits, overloads, and arc faults. The incorporated arc fault module detects and identifies arc faults, which enables the product effectively disconnect the protected circuit against arc fault
Application:
AFDD-32, applicable to AC circuits with rated current up to 32A, is widely used for household and similar installations.
The arc fault detection module of AFDD-32 can effectively detect and identify arc faults that happened to different circuits connected in series, in parallel, and to earth resulting from disabled insulation layers due to aging, damage, or high humidity. The product trips and disconnects a protected circuit upon detection of arc faults.
Main technical parameters:
1)Rated voltage(Ue): AC230V 
2)Rated frequency:50HZ±2%
3)Rated insulation voltage(Ui): 400V 
4)Rated impulse withstand voltage(Uimp):4KV
5)Rated current(In):6A,10A,16A,20A,25A,32A 
6)Magnetic tripping type: B-type, C-type 
7)Rated service short circuit capacity(Ics):6KA 
8)Rated short circuit capacity(Icn): 6KA 
9)Insulation material class: III a 
10)Grid distance(mm):40mm
Classification:
Classified by rated current: 6A, 10A,16A,201,25A,32A 
Classified by magnetic tripping type: B and C type
Normal operating conditions:
The ambient temperature is 5ºC or+40ºC, and the average daily highest temperature is+35ºC. 
Relative humidity: Maximum value is 50% when the temperature is 40ºC and 90% when the temperature is 20ºC.
Arc Fault Breaker Geya 32A Zhe 25A Afdd Protection Gddf
Arc Fault Breaker Geya 32A Zhe 25A Afdd Protection GddfArc Fault Breaker Geya 32A Zhe 25A Afdd Protection Gddf

Recommend Product
Arc Fault Breaker Geya 32A Zhe 25A Afdd Protection Gddf
Arc Fault Breaker Geya 32A Zhe 25A Afdd Protection Gddf
Arc Fault Breaker Geya 32A Zhe 25A Afdd Protection Gddf

 

Company Profile

Arc Fault Breaker Geya 32A Zhe 25A Afdd Protection GddfArc Fault Breaker Geya 32A Zhe 25A Afdd Protection GddfArc Fault Breaker Geya 32A Zhe 25A Afdd Protection GddfArc Fault Breaker Geya 32A Zhe 25A Afdd Protection GddfArc Fault Breaker Geya 32A Zhe 25A Afdd Protection Gddf

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours