Basic Info.
Model NO.
MNS
Rated Frequency
50/60Hz
Rated Voltage
380/660V
Rated Current
400-3150A
Protection Level
IP30-54
Rated Insulation Voltage
660/1000V
Maximum Working Current of Main and Bus
5000A
The Main Bus Is Rated to Withstand Curre
100ka/1s
Main Bus Rated Peak Current Tolerance
220ka/0.1s
Distribution Busbar Working Current
1000A
Distribution Busbar Peak Current
102-176ka/0.1s
Transport Package
Wooden Case
Specification
1000*1000*2200mm
Trademark
CNKC
Origin
China
Production Capacity
1000PCS/Monthly
Product Description
Product Description
Switch cabinet is through the comprehensive type test, and through the national compulsory product 3C certification. The product conforms to GB7251.1 "low-voltage switchgear and control equipment", EC60439-1 "low-voltage switchgear and control equipment" and other standards.
According to your needs or different occasions of use, the cabinet can be installed in a variety of models and specifications of components;According to different electrical equipment, multiple types of feeding units can be installed in the same column cabinet or the same cabinet.For example: feed circuit and motor control circuit can be mixed together. MNS is a full range of low voltage switchgear to meet your full range of requirements. Suitable for all low pressure systems up to 4000A. MNS can provide a high level of reliability and security.
The humanized design strengthens the necessary protection for personal and equipment safety. MNS is a fully assembled structure, and its unique profile structure and connection mode as well as the compatibility of various components can meet the requirements of harsh construction period and power supply continuity.
Model Description
Product technical parameters and installation
Product features
MNS low-voltage pull-out switch cabinet is assembled into modules in factories for ac 50-60Hz, rated working voltage below 660V power supply system MNS switch cabinet is suitable for power supply systems, power plants, substations, industrial and mining enterprises, high-rise buildings, airports, stations, terminals, etc., using 50-60Hz AC, voltage 660V, Power distribution, motor and electrical equipment control, start-up, lighting, power conversion functions, power factor correction.
Environment condition
1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h.
2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M.
3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually.
4. Installation gradient not exceed 5.
5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components.
6. Any specific requirement, consult with manufactory.