Basic Info.
Model NO.
GGD-1250A
Type
Ggd
Name
Switchgear
Voltage
400V
Use for
Power Distribution
Another Name
Motor Control Center
Phase
3 Phase
Frequency
50 Hz
Transport Package
Plywood
Specification
2000*800*800
Trademark
SHME
Origin
China
HS Code
8537109090
Production Capacity
1000set/Year
Product Description
GGD Fixed Type Low voltage Switchgear
GGD type LV low voltage distribution cabinet is based on the higher charge of energy department and the power consumers and design department requirements , the principle of safety, economy, reasonable, reliable design of new type low-voltage distribution cabinet . The products with high breaking capacity, dynamic thermal stability, electrical flexible, convenient combination, a series of practical., novel structure, high protection level, which can be used as a replacement of low voltage switchgear.GGD AC low voltage distribution cabinet is accords with the standards IEC60439 <Low voltage complete switch device and Control Equipment>.
Service conditions1.Ambient air temperature: -30ºC~+50ºC and the average temperature should not exceed +50ºC in 24h 2.Indoor altitude above sea level: Maximum installation altitude: 2500m 3.Relative humidity should not exceed 50% at max temperature +40ºC. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20ºC. But in view of the temperature change, it is possible that moderate dews will produce casually. 4.No fire, explosion danger, serious pollution, chemical corrosion and severe vibration 5.Installation gradient not exceed 5° 6.The equipment shall be installed in a place where there is no violent vibration and impact, and the place where the electrical components are not corroded. 7.Any specific requirement, consult with manufacture
Structural drawings
Electrical properties
1. Basic electrical parameters
2. Main circuit scheme The main circuit of the GGD cabinet is designed with 129 schemes, which have 298 specifications (excluding the function of the auxiliary circuit and the change of the control voltage Among :GGD1 type 49 schemes 123 specifications GGD2 type 53 schemes 107 specifications GGD3 type 27 schemes 68 specifications The main circuit scheme is for the design, use departments suggestions to select, increasing the power plant needs. Rated current to 3150A, suitable for 2000kVA and below distribution transformer selection. In addition, in order to meet the needs of the reactive power compensation designing of GGJ 1, GGJ2 capacitor compensation cabinet, its main circuit 4 schemes. a total of 12 specifications.
3. Auxiliary circuit scheme The design of auxiliary circuit is divided into two parts: power supply scheme and power plant project, GGD cabinet will have enough space to install the secondary components, while NLS has developed special LMZ3D type current transformer to meet power plant and special user with relay protection needs.
4.Main bus Considering the feasibility on price ratio and aluminum replacing copper , the rated current in 1500A and below, it can be used in single row aluminum busbar, rated current is greater than 1500A ,adopting double copper busbar, manufacturer is according to the provisions to produce prototype and passed the type test, of course, the production plant can also be based on user requirements to replace aluminum busbar to change the same carrying capacity of copper bus bar . The lap surface of busbar are used soldering process
Busbar1
Busbar2
Internal view
Our project at site, PT. Gunung Raja Paksi Tbk Indonesia 2×20MW power plant project
PT. GUNUNG RAJA PAKSI TBK is located in Bekasi, West Java, Indonesia and is part of the Iron and Steel Mills and Ferroalloy Manufacturing Industry. PT. GUNUNG RAJA PAKSI TBK has 4,000 total employees across all of its locations and generates $613.01 million in sales (USD). (Employees figure is estimated).