0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer

Introducing our latest product, the 0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer. Made by a trusted factory.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
GWCT01
Frequency Characteristics
Power Frequency
Shape of Core
Od
Phase
Single or Three
Brand
Grewin
Design Advantage
Clamp on Current Transformer
0.333 1.5 Output Clamp on Currenaccuracy
0.5 / 1.0 / 3.0 Electric Energy Field Metering
Split Core Transformer Input
5-630A Electric Energy Field Metering
Split Core Transformer Output
0.333 1.5 Output 0.333 1.5 Output Clamp on Current
0.333 1.5 Output Clamp on Curwindow Size
Check Specification Below
Rated Frequency
50-400kHz Used on Electric Energy Field Metering
Dielectric Strength
1000mohms @ 500 VDC
Operating Temp
-25 C~+75 C 0.333 1.5 Output Clamp on Current Prob
Internal Structure
Epoxy Used on Electric Energy Field Metering
Export Markets
Global
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE
Trademark
grewin
Origin
China
HS Code
850450000
Production Capacity
50000 PCS /Week

Product Description

  

Product Description

1.Product :0.5 class output 0.333v  1000A Input Clamp on Current Transfomer
0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer
0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer


0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer

2.specifications(Current probe)
Rated Primary current 0.1A-1000A
Output signal mA/A or mV/A
 Maximum Non-Destructive Current 2000A
Basic Accuracy 1%
Safety CAT III 600V
Dielectric Resistance 1000MOhms @ 500 Vdc
Case Material Polypropylene resinUL flame retardant rating 94-V0
Voltage rank 600Vac(isolated condition), 30Vac(bareness condition)
Maximum voltage 600Vac
Useable frequency 10Hz - 100kHz
Maximum Cable Diameter 2.05 inches (52 mm)
 Dimensions  4.37x8.5 x1.77 in. (111x216x45 mm)
Operating Temperature -10ºC to +50ºC
Standard IEC 60044-1
Accessories Supplied with feet for base mounting if required
Certification RoHS compliant CE&ETL approved

3.features(Current probe)
Good appearance
Low cost
5 standard sizes
Clamp-on core design,safer,easier installation, portable
Both Silicon Steel & Nickel Alloy cores available
Current or three specs voltage output signal 

4.applications(Current probe)
Current, power energy,monitoring devices
Power Factor Correction devices
Oscilloscope and harmonic waves analyzer

5.Details of the data
 
Part number Input current Rated Output Frequency
(Hz)
Secondary
Burden
Resistance
Accuracy
Class
GWCTP1535 0.5-1000A 1mA/A 40-1KHZ ≤10 Ohms 1%
400-1000A 5A,1A 50/60HZ ≤2VA 1%
0.1-10A 100mV/A 10-1000K ≥100KOhms 3%±10mV
0.1-100A 10mV/A 2%±5mV
1-1000A 1mV/A 1%±1mV
0.5-1000A 4-20mA 50/60HZ ≤100 Ohms 1%

 6.Characteristic performance curve and size
0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer

We can produce following similar clamp on current transformer:
1.Product picture

0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer

2.specifications(1-200A Clamp on current transformer)
Rated Primary current 1-200A
Turn ratio 1:1000 1:2000 1:2500
Output 0.333V 1.5V
Accuracy 0.1, 0.2 ,1.0 Class
Second burden(Ohms) <=5, <=50 ,>=100k
Dielectric Resistance 1000MOhms @ 500 Vdc
Case Material Polypropylene resinUL flame retardant rating 94-V0
Voltage rank 600Vac(isolated condition), 30Vac(bareness condition)
High Potential 2500Volts/min
Frequency Range: 50/60Hz
Operating Temperature -25ºC to +70ºC
Standard IEC 60044-1
Accessories Supplied with feet for base mounting if required
Certification RoHS compliant CE&ETL approved

3. features(Clamp on current transformer)
Low cost
5 standard sizes
 Clamp-on core design,safer,easier installation, portable
Both Silicon Steel & Nickel Alloy cores available

4.applications(Clamp on current transformer)
Silicon Steel cores provide moderate accuracy and lower cost for appropriate current measurement
Nickel Alloy cores are suitable for applications that require the highest accuracy with minimal phase angle error. Applications would include electric power quality monitoring devices

Company introductio n
1.certification

We have passed ISO9001:2015,CE,SGS approval and IEC report
0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer
0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer


2.Company profile
     Tianjin Grewin is concentrating on transformers for 20 Years and complianted by ISO9001:2015,CB,IEC CB,CE etc.We're always pay great attention to its business philosophy "Quality and Honesty First".Our main product are Miniature votage transformer ,Miniature current transformer ,Instrument current transformer , Split Core Current Transformer, clamp on current transformer ,zero-flux current transformer ,three phase current transformer ,hall sensors .windely used in communications,electronics,meters,industrial control,medical equipments and other fields.We are also a provider of power meters and instruments locators. 85% of its products exported to America, Europe, and Asia etc.We sincerely invite you to join us to create a bright future.

0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer

3.Terms of Shipment:
(1)Products are shipped via UPS / DHL / EMS / HK EMS /     FedEx / TNT and so on expresses (door to door).
(2)We Provide Drop shipping Service.
(3)20 days around delivery upon receiving payment if the qty    is lower than 1000PCS and it is not customized products.
(4)In order to ensure you receive your order tax free upon  
import, we declare lower value.
(5)Shipping via EMS. UPS. FedEx and TNT express usually     takes 3~7days dependent on the destination country.

4.Payment terms:
(1)T/T 100% or 50% deposit by T/T in advance, balance amount to be paid 7 days before
delivery.
(2) By irrevocable L/C at sight, to be issued immediately against confirmed order.
(3)Payment by T/T, if order amount is less than USD 20,000.

5.Warranty:
(1)We provide 1 year warranty.
(2)If the product is defective, please notify us within 3 days of delivery.
(3)All products must be returned on their original condition, in order to qualify for a refund or exchange of goods

6.Production
The following picture showed you about all finished transformer production line and package with export standard carton and strong pallets:
0.5 Class Output 0.333V 1000A Input Clamp on Current Transfomer for Oscilloscope and Harmonic Waves Analyzer

7.Flow chart of trading activities:


NO

Step

Days need

1

Request for quotation

1 day

2

Making quotations

1 day

3

Offer and counter offer

3 days

4

Sending and receiving samples

3-10 days

5

Sample confirmation

3 days

6

Placing a firm order

1 day

7

Paying and receiving the down payment

1-4 day

8

Factory production & Quality inspection

15-20 days

9

Paying and receiving the balance

4 days

10

Delivery of goods

1 days

8.Why choose us?
Quality and honest first!
A. Flexible service for diffierent current transformers with high efficiency performance.
B. Over 40 years experience of current transformer designing and producing.
C.100% test of every single product we produce from incoming material checking.
D. UL, CE, ISO9001:2008
E. We offer custom-made current transformers, OEM and ODM are welcome
F. We deliver the quality you expect at consistently competitive prices
G.Current transformer quality lifetime:10 Years.
H.Specialty Sales service:5 -10 Years

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours