Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB

Get reliable RCCB ELCB protection with our 30mA 63AMP RCD 4p Type B ELCB. As a factory, we ensure top quality and safety. Buy now!
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
AG-VDF-2B-63A
Arc-extinguishing Medium
SF6
Installation
Insert
Structure
ELCB
Poles Number
1
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
CE, CB, CCC
Mode
Electro-Magnetic Type
Rated Voltage
AC 230(240)/400(415)
Electro-Mechanical Endurance
4000 Cycle
Protection
IP20
Terminal Connection Height: 19mm
19mm
Connection Terminal
Screw Terminal
Supply Ability
10000 Pole/Poles Per Month
Transport Package
Carton
Specification
36*78*81mm
Trademark
AEGEN
Origin
China
HS Code
8538900000
Production Capacity
10000 Pole/Poles Per Month

Packaging & Delivery

Package Size
40.50cm * 19.50cm * 18.50cm
Package Gross Weight
5.800kg

Product Description

Product Description

Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB
Residual current circuit breakers (RCCBs) 

This device is essentially a  attached to it. So basically it will only break the circuit when there is a leakage current flowing to earth. The tripping time is such as to minimise the risk to human life.

RCCBs usually have a fault making and . This means that they can handle a fault of 1 kA on their own if it is a fault to earth.

Type B residual current device disconnects the power if the earth leakage current is detected as dangerous. If the earth leakage current is equal to or less than 10mA, then the Type B residual current devices would not trip because this current amount is not dangerous. The electric car will continue to get charging without any interruption. The Type B residual current devices will immediately trip the circuit and disconnect the power supply for higher currents. Like this, Type B residual current devices will protect the circuits from danger.
                                                                        Technical Data
Model: AG-VDF-2B-63A
Pole No.: 1P+N, 3P+N
Rated current(A): 16A,25A, 32A, 40A, 63A,80A,100A 
Rated working voltage(I n): 30, 100, 300, 500mA
Rated voltage(V): AC 230(240)/400(415)
Rated frequency(Hz): 50/60
Rated making and breaking capacity: 500(In=25A,32,40A), 630(In=63A)
Rated conditional short-circuit current Inc: 10000A
Rated conditional residual short-circuit Current I c: 10000A
Rated residual non operating current I no: 0.5I n
Residual operating current range: 0.5I n~I n
Operating time: ≤0.3s
Type: A and AC type
Rated short-circuit breaking capacity: 10000A
Mechanical life: 2000 times
Degree of protection: IP20
Products name: Type B RCD | Type B RCCB | Detection residential RCCB 
Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB Earth Leakage Circuit Breaker RCCB 30mA 63AMP RCD 4p Type B ELCB

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours