Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device

Get reliable RCD protected circuits with Geya B Type RCCB 10ka 400V. As a factory, we guarantee high-quality and dependable electrical products.
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
GYL9-B 2P 30mA 16-25A
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
ELCB
Poles Number
2
Type
Circuit Breaker
Function
RCCB
Certification
CE
Current
16-25A
Series
Gyl9-B
Transport Package
Standard Box
Specification
GYL9-B 2P 30mA 16-25A
Trademark
GEYA
Origin
Zhe

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
1.000kg

Product Description

·········This link price si only for GYL9-B 2P 30mA 16-25A··········
Product Description

GYL9 Type B Residual Current Circuit Breaker (RCCB)(without overcurrent protection), suitable for rated voltage 230V at two poles, 400V at four poles, rated current n line 63A, when the person gets an electric shock or the grid leakage current exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply for protecting the safety of human body and electrical equipment can also be used for infrequent switching of circuits and infrequent starting of motors.
 

  • *In compliance with IEC/EN 61008.1, IEC/EN 62423;
  • *Bilateral busbar wiring capabilities to adapt to the wider use of premises.
  • *Maximum connecting ability of 35mm², wiring torque 3.5N*m, applicable to a variety of installing equipment, wiring stronger
  • *Protection class: IP20
Electrical features  
Type(an aware form of the earth leakage sensed) B
Rated current In 25,40,63A
Poles 2P 4P
Number of poles versus modules 2P= 4mod;4P=4 mod
Rated voltage Ue 2P:230V~ 4P:400V~
Insulation voltage UI 500V
Rated frequency 50/60Hz
Rated sensitivity IAn 0.03A 0.1A 0.3A
Rated residual making and breaking capacity Im 500(In=25-40A)630(In=63A)
Short-circuit current lnc=lAc 10000A
SCPD fuse 10000
Break time under IAn ≤0.1S
Rated impulse withstand voltage(1.2/50)Uimp 6000V
Dielectric test voltage at and ind.Freq.for 1min 2.5kV
Electrical life and Mechanical life 4000
Pollution degree 2
Installation  
Fault current indicator NO
Protection degree IP20
Ambient temperature(with a daily average of 35 ) -5~+40°ºC
Storage temperature -25+70ºC
Terminal connection type Cable/U-type busbar/Pin -type busbar
Terminal size top/bottom for cable 35mm²
18-3
Tightening torque 3.5N*m
22
Mounting On DIN rail FN 60715 (35mm)by means of the fast clip device
Connection From top
Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device
Company Profile

 

Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device Geya RCD Protected Circuits B Type RCCB 10ka 400V Residual Circuit Device

Contact us