Honle Zw32 Outdoor High Voltage Vacuum Circuit Breaker Vcb 1250A

Honle Zw32 Outdoor High Voltage Vacuum Circuit Breaker Vcb 1250A from our factory. High-quality, reliable and efficient equipment for power distribution.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
ZW32
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Vcb
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Rated Voltage
12kv, 24kv, or 40.5kv
Rated Frequency
50Hz
Rated Current
630A, 1250A, 2000A, 2500A, or 3150A
Rated Short-Circuit Breaking Current
20ka
Rated Peak Withstand Current (Peak)
50ka
Rated Short-Time Withstand Current
20ka
Rated Short Circuit Closing Current (Pea
50ka
Transport Package
Standard Export Package
Specification
630A-1250A
Trademark
Honle
Origin
Zhejiang, China
Production Capacity
5000PCS/Month

Packaging & Delivery

Package Size
94.80cm * 80.00cm * 73.70cm
Package Gross Weight
20.000kg

Product Description

Honle Zw32 Outdoor High Voltage Vacuum Circuit Breaker Vcb 1250A
Honle Zw32 Outdoor High Voltage Vacuum Circuit Breaker Vcb 1250A
Honle Zw32 Outdoor High Voltage Vacuum Circuit Breaker Vcb 1250A
 
Honle Zw32 Outdoor High Voltage Vacuum Circuit Breaker Vcb 1250A
Description:

ZW32-12,24,40.5 outdoor vacuum circuit breaker (hereinafter referred to as circuit breaker) is an outdoor power distribution equipment with rated voltage of 12KV,24KV or 40.5KV and three-phase AC 50Hz. It is mainly used to break and close the load current, overload current and short circuit current in the power system. It is suitable for protection and control in substation and industrial and mining enterprise substation systems, and places where rural power grids operate frequently.

The circuit breaker has the characteristics of small size, light weight, anti-condensation and maintenance-free, and can adapt to harsh weather conditions and dirty environments.



Standards compliant:

GB1984 "AC high voltage circuit breaker"
GB11022 "Common technical requirements for high-voltage switchgear and control equipment standards"
GB311.1-6 "Insulation coordination of high voltage power transmission and transformation equipment"
GB763 "Communication of AC high voltage electrical appliances during long-term work"
BG2706 "Test Method for Dynamic and Thermal Stability of AC High Voltage Apparatus"
GB3309 "Mechanical test of high voltage switchgear at room temperature"
DL/T593 "Technical Conditions for Common Ordering of High Voltage Switchgear"


 

Sr.

Name

Unit

Value

1

Rated voltage

KV

12,24,40.5

2

Rated frequency

Hz

50

3

Rated current

A

630,1250,2000,2500,3150

4

Rated short-circuit breaking current

KA

20

5

Rated peak withstand current (peak)

KA

50

6

Rated short-time withstand current

KA

20

7

Rated short circuit closing current (peak)

KA

50

8

Mechanical life

Time

10000

9

Rated short circuit current breaking times

Time

30

10

Power frequency withstand voltage (1min): (wet) (dry) phase, ground, fracture

KV

42/48

11

Lightning impulse withstand voltage (peak), phase to ground, fracture

KV

75/85

12

Secondary circuit 1min power frequency withstand voltage

KV

2



 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours