RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell

Get the best deals on RCCB TML2-63 63A 10kA Type A 2P Certification from the leading manufacturer and wholesaler. As a factory, we offer the highest quality at competitive prices. Buy now!
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
Overview

Basic Info.

Model NO.
RCCB TML2-63 63A 10kA Type Ac 2P
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
ISO9001-2000, CE, CB
Standard
IEC/En 62606 & IEC 61009-1
Tripping Curve
B,C
Rated Current (in)
6A,10A,16A,20A,25A,32A,40A
Residual Current Type
Type AC,a
Residual Current (LΔn)
30mA,100mA,300mA
Making Breaking Capacity (IΔm)
2,000A
Energy Limiting Class
3
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Product Description

Product Description

RCD
The Residual Current Device, or RCD, is one of the most important electrical safety devices in both the home and commercial environments.

In short, an RCD protects against injury and death caused by electric shock by detecting an imbalance between the outgoing and incoming total current of a given number of circuits. It works on the very simple principle that if there is a difference in the electricity coming in against that which is going out, then it must have gone somewhere.
This phenomena is commonly known as 'earth leakage' - (or the 'Residual Current' in the RCD's title). It can be caused by a number of problems including poor electrical wiring and DIY accidents such as drilling through a cable when mounting a picture hook or cutting through a cable with the lawn mower. In this type of situation the electricity must go somewhere and choosing the easiest route can travel through the lawnmower or drill to the human holding them to create a circuit and cause electric shock.
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell

                                                                                             The basic structure of RCD

Product Parameters
 
Product category CIRCUIT BREAKER
Product type RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS
Product model TML2-63 63A 10kA Type A 2P
Product photo RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
Business information MOQ: 120pcs
Payment: T/T, L/C
Delivery time: 15-60 days
Loading Port: Ningbo or Shanghai, China
Certification: ISO9001:2015
Logo:pad printing, laser printing  (customized design are acceptable)
Technical data   Standard IEC61008-1, GB16916-1
Electrical features Rated curret (In) 25A, 40A, 63A
Model Electromagnetic
Type AC, A, S, G
Pole 2P, 4P
Rate voltage (Ue) 240/415V
Insulation voltage(Ui) 500V
Rated frequency 50/60Hz
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated conditional short-circuit current Inc) 10KA
Rated residual making and breaking capacity(IΔm) 1000A
Rated impulse withstand voltage (Uimp) 4KV
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 10,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 25mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 2.5Nm
35mm DIN rail

 
FAQ
What is RCD?
The Residual Current Device, or RCD, is one of the most important electrical safety devices in both the home and commercial environments.
In short, an RCD protects against injury and death caused by electric shock by detecting an imbalance between the outgoing and incoming total current of a given number of circuits. It works on the very simple principle that if there is a difference in the electricity coming in against that which is going out, then it must have gone somewhere.
This phenomena is commonly known as 'earth leakage' - (or the 'Residual Current' in the RCD's title). It can be caused by a number of problems including poor electrical wiring and DIY accidents such as drilling through a cable when mounting a picture hook or cutting through a cable with the lawn mower. In this type of situation the electricity must go somewhere and choosing the easiest route can travel through the lawnmower or drill to the human holding them to create a circuit and cause electric shock.

RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
                                                                                           The basic structure of RCD

How do RCD Works - The Power of Electromagnetism
Residual Current Devices (RCDs), also known as Ground Fault Circuit Interrupters (GFCIs) in some regions, are safety devices designed to protect against electric shock and electrical fires. RCDs work by constantly monitoring the electrical current flowing in a circuit. If they detect a mismatch in the incoming and outgoing current, which could indicate a leakage of current to the ground, they quickly cut off the power supply to prevent the risk of electric shock. This rapid disconnection helps to protect people from potential harm due to electric shock and also reduces the risk of electrical fires. RCDs are an important safety feature in modern electrical installations and are commonly used in homes, workplaces, and other settings where electrical appliances are used.


RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell

How the RCD Prevents Injury - Milliamps and MillisecondsAn electrical current of just a few milliamps (mA) experienced for just one second is enough to kill most fit, healthy people. RCDs therefore have two key aspects to their operation - the amount of current they allow for Earth Leakage before operating - the mA rating - and the speed with which they operate - the ms rating.

RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell what is the difference of ELE and ELM RCD?
The electromagnetic leakage circuit breaker does not require auxiliary power, and there is no circuit board component inside. It has nothing to do with the working voltage of the switch. As long as the leakage current of the line reaches the electromagnetic leakage action current, the leakage circuit breaker will act to cut off the power supply behind it and protect personal safety.
The electronic leakage circuit breaker requires auxiliary power, which comes from the output terminals (load side) of the leakage circuit breaker. It is related to the working voltage of the line. If the voltage is too low, even if there is leakage current in the line and it reaches the leakage current action value of the switch, the switch will not operate.




Do I need to install RCD?
Yes, it is highly recommended where there is an increased risk of fire:
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sellRCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell

 
Our Advantages

Timelec RCD (RCCB) total length, 115mm.
Compact yet not a compromise.

It is your best choice for overall protection and prevention in domestic and commercial applications.

Timelec offers customization:

Print: laser / pad;
Package: white gift box for selected product types for value adding;
                    yellow carton box for full range as bulk package.
Product design: based on volume to open new mould.
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
 
Certifications
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell

 

Packaging & Shipping

White gift box: 1 pcs / gift box;

RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell


Yellow carton box: 60 pcs / carton box.

RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell
As a package in the distribution channel,
Timelec offers a corrugated carton box:

High quality,
High edge crush resistence,
Neutral print in black.
 

 

Installation Instructions

 

RCCB TML2-63 63A 10kA Type A 2P Certification Manufacturer Whole sell

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours