Basic Info.
Model NO.
JLR2-D
Electricity Type
Ac
Number of Pole
3
Load
Medium Power Relay
Protective Characteristics
Over Load Protetion
Action Principle
Electromagnetic Type
Size
Miniature
Type
Thermal Overload Relay
Relay Type
Thermal Relay
Protection
Thermal Overload
Transport Package
Cartons
Specification
silver contact point
Trademark
CNJUHO
Origin
Zhejiang
HS Code
8536490000
Production Capacity
1000000
Product Description
1.Application:
JRS4-d range thermal overload relay is used in AC 50Hz (or 60Hz); rated voltage is up to 660V, for protecting AC motor against overload or phase-breaking.
Product feature △ Delta bimetallic strip; △ three phase; △ trip level "10"; △ with setting current regulating device; △ with ambient air temperature compensation; △ with phase failure protection; △ manual and automatic reset; △ with trip indication; △ the auxiliary contact is a normally open contact and a normally closed contact separated electrically; △ there is a normally closed contact breaking button; △ There is a mechanism detection button.
Applied environment △ Ambient temperature:-5ºC-+40ºC; △ Air condition:be able to bear the influence of moisture in the air,salt fog,mould,humid air on the sea; △ Tilt and vibration:all direction should low than 22.5ºC; △ Vibration:It can be mounted on devices with 2-13.2Hz frequency,±1mm anplitude,13.2-80Hz frequency and ±7m/s accelerated speed. △Power voltage and frequency changes:steady-state voltage area is+6%- -10% of rated voltage,steady-state frequency change area is±5% of rated frequency; △The inclined angle between the mounting surface and vertical surface
no more than 5 °,located on the place of non-sensible compact and vibration.
no more than 5 °,located on the place of non-sensible compact and vibration.
2.Technical Parameter
Model Name |
| protection relay |
Standard |
| IEC60947-4-1 |
Setting current multiple |
| 1.05, 1.2, 1.5, 7.2 |
Rated current In(A) |
| 25 36 93Amp |
Rated voltage Un(V) |
| 230V 240V 380V |
Frequency of coil |
| 50Hz, 60Hz, 50/60Hz |
Number of auxiliary contact |
| 10 /01 /11 |
Protection grade |
| IP20 |
Pollution grade |
| 3 |
3.Main parameter
Type Parameter | JRS4-09d-25d | JRS4-32d | JRS4-40d-80d | JRS4-140d | |
Rated Insulation voltage Ui V | 690 | ||||
-5-40 | |||||
Ambient temperature(ºC) | ≤2000 | ||||
Elevation | Relative humidity not exceeding 50% at the ambient temperature 40ºC humidity up to 90% at the ambient temperature 20ºC | ||||
Environment | 690 | ||||
Standard | IEC60947-4 EN60947-4 | ||||
Pollution grade | Grade 3 | ||||
Our frame protection | IP10 | ||||
Connect minimum load of attached circle | 24V 100mA | ||||
Lead No.Of main circuit connect terminal | Solft wire(mm2) | 4 | 10 | 16 | - |
Hard wire(mm2) | 6 | 16 | 25 | 50 | |
root | 2 | 2 | 1 | 1 |