Basic Info.
Packaging & Delivery
Product Description
AFCI, Arc Fault Circuit Interrupter, or being called AFDD, Arc Fault Detection Device, in comply wtih IEC/BS EN 62606.
In terms of circuit protection,Timelec has MCB for short-circuit and overload protection, RCD (RCCB) for residual current protection; yet not safe enough. According to statistics, in terms of electrical safety, 90% of fires are caused by electric arc, and we need AFDD for arc protection.
Timelec AFDD is AFDD+RCBO, offering short-circuit, overload, residual current, arc and over-voltage protection, meeting the standard of IEC/BS EN 62606 and IEC/BS EN 61009-1, and it selectively distinguishes a harmless arc from a potentially dangerous arc. For example, it breaks the circuit when it detects electric arc which is a signature of loose connections in home-wiring, as loose connection can develop over time and sometimes become hot enough to cause house fires.
Product category | CIRCUIT BREAKER | ||
Product type | ARC FAULT DETECTION DEVICES (AFDDs) | ||
Product model | TMA1-40 | ||
Unique selling proposition | With AFD+RCBO protection With Over-vol. protection Total length, 115mm | ||
Technical data | Standard | IEC/EN 62606 & IEC 61009-1 | |
Electrical features | Rated curret (In) | 6A,10A,16A,20A,25A,32A,40A | |
Trip curve | B, C, D | ||
Model | Electronic | ||
RCD Type | AC, A | ||
Pole | 1P+N | ||
Rate voltage (Ue) | 240V | ||
Insulation voltage(Ui) | 500V | ||
Rated frequency | 50Hz | ||
Energy limiting class | 3 | ||
Rated residual operating current (IΔn) | 30mA, 100mA, 300mA | ||
Rated breaking capacity (Icn) | 6KA | ||
Rated operating short circuit breaking capacity (Ics) | 6KA | ||
Rated residual making and breaking capacity(IΔm) | 2000A | ||
Rated impulse withstand voltage (Uimp) | 4KV | ||
Surge current resistance / at (8/20) μs | 3KA | ||
Overvoltage protection | 270V-300V | ||
Electrical life | 4,000 | ||
Pollution degree | 2 | ||
Mechanical features | Mechanical life | 20,000 | |
Protection degree | IP20 | ||
Ambient temperature (with daily averages35°C) | -25°C +40°C | ||
Storage temperature | -25°C +70°C | ||
Installation | Terminal connection type | Cable, busbar | |
Connection capacity (input) | 25mm2 | ||
Connection capacity (output) | 16mm2 | ||
Tightening torque (input) | 2.5Nm | ||
Tightening torque (output) | 1.2Nm | ||
35mm DIN rail |
What are arcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
What causes arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.
Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
What is AFCI?
AFCI is circuit interrupter installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.
It will cut off the power to the affected circuit and could prevent a fire.
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire:
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Circuit Interrupers are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.
Since 2014, IEC 60364 recommends surrounding the installation and application environments of AFDDs in residential and commercial buildings:
More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Timelec AFCI(AFDD) total length, 115mm.
Compact yet not a compromise.
It is your best choice for overall protection and prevention in domestic and commercial applications.